INPUTS
|
8 Differential Inputs - These can be Millivolt, D.C. current, thermocouple , load and strain gauges etc.
Excitation - 5 or 10 V DC at 100mA max excitation available for sensors for pressure, load cells etc.
|
OUTPUTS
|
2 Normally Open Relays - 2 alarms per channel available set to Hi/Hi, Hi/lo, Lo/Lo or off and tagged to the two normally open relays sharing a common feed.
|
LOGGING INTERVAL
|
Selectable - 1 second to 12 Hours in 1 second increments
|
MEMORY
|
RAM - Optional 1 MB RAM (1MB = 500K readings) and real time clock for off line applications.
|
AMBIENT RANGE
|
Temperature - 0 to 40 Deg, 90% RH (non condensing)
|
COMMUNICATION
|
RS232/485 - Standard RS232 and RS485 to computer. USB for local setup
|
CONNECTIONS
|
Internal Connectors - 2 part screw terminals on 5mm pitch for easy installation
|
POWER
|
Mains or DC Version - 115/230V 50/60 Hz @ approx. 12VA (optional DC Version).
|
CASE
|
IP65 Case - Instrument is housed in a robust IP65
|